{"id":3071,"date":"2023-01-08T15:46:59","date_gmt":"2023-01-08T21:46:59","guid":{"rendered":"https:\/\/nuevo22.cidsamexico.com\/?post_type=al_product&#038;p=3071"},"modified":"2023-01-20T16:48:21","modified_gmt":"2023-01-20T22:48:21","slug":"cell-meter-intracellular-colorimetric-lipid-peroxidation-mda-assay-kit-2","status":"publish","type":"al_product","link":"https:\/\/nuevo22.cidsamexico.com\/index.php\/productos\/cell-meter-intracellular-colorimetric-lipid-peroxidation-mda-assay-kit-2\/","title":{"rendered":"Cell Meter\u2122 Intracellular Colorimetric Lipid Peroxidation (MDA) Assay Kit"},"content":{"rendered":"\n<p>La peroxidaci\u00f3n lip\u00eddica se caracteriza por la degradaci\u00f3n oxidativa de los \u00e1cidos grasos insaturados, fosfol\u00edpidos, glicol\u00edpidos, \u00e9steres de colesterol y colesterol. El malondialdeh\u00eddo (MDA) es uno de los biomarcadores m\u00e1s utilizados para la peroxidaci\u00f3n lip\u00eddica. Hist\u00f3ricamente, la medici\u00f3n de MDA se ha basado en una reacci\u00f3n con \u00e1cido tiobarbit\u00farico (TBA) para generar un producto que se puede medir colorim\u00e9trica o fluorom\u00e9tricamente. Sin embargo, el ensayo TBA tiene bastantes limitaciones. (1). La reacci\u00f3n no es espec\u00edfica de la MDA. (2). La reacci\u00f3n de TBA-MDA debe realizarse en condiciones \u00e1cidas. (3). Los ensayos deben realizarse a alta temperatura, normalmente entre 90 y 100 \u00baC. <\/p>\n\n\n\n<p>Los ensayos comerciales de MDA basados \u200b\u200ben TBA son extremadamente tediosos debido a estas limitaciones. Este kit de cuantificaci\u00f3n de peroxidaci\u00f3n lip\u00eddica (MDA) colorim\u00e9trica Cell Meter\u2122 ofrece el m\u00e9todo m\u00e1s r\u00e1pido y conveniente para medir MDA sin los pasos de calentamiento TBARS. MDA Blue\u2122 reacciona con MDA para generar un producto de color azul que se mide a 695 nm con un lector de microplacas de absorbancia. Este ensayo es muy r\u00e1pido y espec\u00edfico para MDA con poca interferencia de otros aldeh\u00eddos.\u00a0 Kit para 200 pruebas.<\/p>\n\n\n\n<div style=\"height:26px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\" style=\"font-size:18px\"><table class=\"has-black-color has-text-color has-background\" style=\"background:linear-gradient(0deg,rgb(238,238,238) 0%,rgb(255,255,255) 28%,rgb(249,249,249) 72%,rgb(169,184,195) 100%)\"><thead><tr><th>Catalogo<\/th><th>Producto<\/th><th>Presentaci\u00f3n<\/th><\/tr><\/thead><tbody><tr><td>AAT-15991<\/td><td>Cell Meter\u2122 Intracellular Colorimetric Lipid Peroxidation (MDA) Assay Kit<\/td><td>200 pruebas<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:12px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-container-1 is-nowrap wp-block-group\">\n<figure class=\"wp-block-image\"><img src=\"https:\/\/images.aatbio.com\/dependencies\/icon_pdf.png\" alt=\"pdf\"\/><\/figure>\n\n\n\n<p><a href=\"https:\/\/docs.aatbio.com\/products\/safety-data-sheet-sds\/safety-data-sheet-for-cell-meter-intracellular-colorimetric-lipid-peroxidation-mda-assay-kit-catalog-15991.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">SDS<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img src=\"https:\/\/images.aatbio.com\/dependencies\/icon_pdf.png\" alt=\"pdf\"\/><\/figure>\n\n\n\n<p><a href=\"https:\/\/docs.aatbio.com\/products\/protocol-and-product-information-sheet-pis\/protocol-for-cell-meter-intracellular-colorimetric-lipid-peroxidation-mda-assay-kit-version-ktIVB16dMP.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Protocol<\/a><\/p>\n<\/div>\n\n\n\n<p>Importante: Solo para uso en investigaci\u00f3n (RUO). <\/p>\n\n\n\n<div style=\"height:55px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Plataforma<\/mark><\/p>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">Lector de Microplacas de Absorbancia<\/mark> <\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Absorbancia<\/td><td>695 nm<\/td><\/tr><tr><td>Placa recomendada<\/td><td>Fondo transparente<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:48px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Componentes<\/mark><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Componente A: MDA Blue\u2122<\/td><td>1 vial<\/td><\/tr><tr><td>Componente B: Buffer de diluci\u00f3n<\/td><td>1 botella (10 mL)<\/td><\/tr><tr><td>Componente C: MDA Standard<\/td><td>1 vial (liofilizado)<\/td><\/tr><tr><td>Componente D: Solucion de reacci\u00f3n<\/td><td>1 botella (10 mL)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:54px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-container-2 wp-block-group has-background\" style=\"background-color:#fafafa\"><div class=\"wp-block-group__inner-container\">\n<p style=\"font-size:16px\">PREPARACION DE SOLUCIONES DE STOCK<\/p>\n\n\n\n<p style=\"font-size:16px\"><em>A menos que se indique lo contrario, todas las soluciones madre no utilizadas deben dividirse en al\u00edcuotas de un solo uso y almacenarse a -20 \u00b0C despu\u00e9s de la preparaci\u00f3n. Evite los ciclos repetidos de congelaci\u00f3n y descongelaci\u00f3n.   <\/em><\/p>\n\n\n\n<p style=\"font-size:16px\"><em>Soluci\u00f3n madre est\u00e1ndar de MDA (100 mM)<\/em><br>Agregue 100 \u00b5l de ddH2O al est\u00e1ndar MDA (componente C) y m\u00e9zclelos bien. Nota: La soluci\u00f3n madre de MDA no utilizada debe almacenarse a -20 \u00b0C en al\u00edcuotas de un solo uso.<\/p>\n<\/div><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<div class=\"wp-container-3 wp-block-group has-background\" style=\"background-color:#fafafa\"><div class=\"wp-block-group__inner-container\">\n<p style=\"font-size:16px\">PREPARACION DE SOLUCION ESTANDAR<\/p>\n\n\n\n<p style=\"font-size:16px\">Para mayor comodidad, utilice el Planificador de diluci\u00f3n en serie:<br><a href=\"https:\/\/www.aatbio.com\/tools\/serial-dilution\/15991\" target=\"_blank\" rel=\"noopener\" title=\"\">https:\/\/www.aatbio.com\/tools\/serial-dilution\/15991<\/a><\/p>\n\n\n\n<p style=\"font-size:16px\"><em>Est\u00e1ndar MDA<\/em><br>Agregue 10 \u03bcL de est\u00e1ndar MDA (100 mM) en 990 \u03bcL de buffer de diluci\u00f3n (componente B) para obtener una soluci\u00f3n est\u00e1ndar de MDA (1000 \u03bcM). A continuaci\u00f3n, realice diluciones en serie en el buffer de diluci\u00f3n para obtener est\u00e1ndares de MDA diluidos en serie de 800, 600, 400, 200, 100, 50 y 0 \u03bcM.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:56px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-container-4 wp-block-group has-background\" style=\"background-color:#fafafa\"><div class=\"wp-block-group__inner-container\"><\/div><\/div>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Imagenes<\/mark><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"893\" height=\"288\" src=\"https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-79.png\" alt=\"\" class=\"wp-image-3079\" srcset=\"https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-79.png 893w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-79-300x97.png 300w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-79-768x248.png 768w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-79-600x194.png 600w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-79-280x90.png 280w\" sizes=\"(max-width: 893px) 100vw, 893px\" \/><\/figure>\n\n\n\n<p style=\"font-size:16px\"><strong>Figura 1<\/strong>. . La respuesta a la dosis de MDA se midi\u00f3 con el kit de cuantificaci\u00f3n de peroxidaci\u00f3n lip\u00eddica colorim\u00e9trica (MDA) Amplite\u00ae en una microplaca de fondo transparente de 96 p pozos utilizando un lector de microplacas SpectraMax (Molecular Devices). (Pathcheck activado (Imagen izquierda); Pathcheck desactivado (Imagen derecha))<\/p>\n\n\n\n<div style=\"height:62px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"429\" height=\"310\" src=\"https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-80.png\" alt=\"\" class=\"wp-image-3080\" srcset=\"https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-80.png 429w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-80-300x217.png 300w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-80-221x160.png 221w\" sizes=\"(max-width: 429px) 100vw, 429px\" \/><figcaption>Fig. 2<\/figcaption><\/figure>\n\n\n\n<p style=\"font-size:16px\"><strong>Figura 2<\/strong>. Comparaci\u00f3n de se\u00f1ales de MDA, formaldeh\u00eddo y gliceraldeh\u00eddo.<\/p>\n\n\n\n<div style=\"height:68px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" width=\"500\" height=\"400\" src=\"https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-81.png\" alt=\"\" class=\"wp-image-3081\" srcset=\"https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-81.png 500w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-81-300x240.png 300w, https:\/\/nuevo22.cidsamexico.com\/wp-content\/uploads\/2023\/01\/image-81-200x160.png 200w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><figcaption>Fig. 3<\/figcaption><\/figure>\n\n\n\n<p style=\"font-size:16px\"><strong>Figura 3<\/strong>. La respuesta a la dosis de MDA se midi\u00f3 con el kit de cuantificaci\u00f3n de peroxidaci\u00f3n lip\u00eddica colorim\u00e9trica (MDA) Amplite\u00ae en una microplaca de fondo transparente de 96 pocillos utilizando un lector de microplacas SpectraMax (Molecular Devices).<\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Bibliograf\u00eda<\/mark><\/mark><\/mark><\/p>\n\n\n\n<p style=\"font-size:14px\">Assessment of lipid peroxidation by measuring malondialdehyde (MDA) and relatives in biological samples: Analytical and biological challenges.<br><strong>Authors:&nbsp;<\/strong>Tsikas D., undefined<br><strong>Journal:&nbsp;<\/strong>Anal Biochem&nbsp;(2016)<\/p>\n\n\n\n<p style=\"font-size:14px\">Formation of Malondialdehyde, 4-Hydroxynonenal, and 4-Hydroxyhexenal during in Vitro Digestion of Cooked Beef, Pork, Chicken, and Salmon<br><strong>Authors:&nbsp;<\/strong>Steppeler C, Haugen JE, Rodbotten R, Kirkhus B.<br><strong>Journal:&nbsp;<\/strong>J Agric Food Chem&nbsp;(2016):&nbsp;487<\/p>\n\n\n\n<p style=\"font-size:14px\">Development, validation and biomedical applications of stable-isotope dilution GC-MS and GC-MS\/MS techniques for circulating malondialdehyde (MDA) after pentafluorobenzyl bromide derivatization: MDA as a biomarker of oxidative stress and its relation to 15<br><strong>Authors:&nbsp;<\/strong>Tsikas D, Rothmann S, Schneider JY, Suchy MT, Trettin A, Modun D, Stuke N, Maassen N, Frolich JC.<br><strong>Journal:&nbsp;<\/strong>J Chromatogr B Analyt Technol Biomed Life Sci&nbsp;(2016):&nbsp;95<\/p>\n\n\n\n<p style=\"font-size:14px\">Plasma malondialdehyde as biomarker of lipid peroxidation: effects of acute exercise<br><strong>Authors:&nbsp;<\/strong>Spirl, undefined and eli AL, Deminice R, Jordao AA.<br><strong>Journal:&nbsp;<\/strong>Int J Sports Med&nbsp;(2014):&nbsp;14<\/p>\n\n\n\n<p style=\"font-size:14px\">A specific, accurate, and sensitive measure of total plasma malondialdehyde by HPLC<br><strong>Authors:&nbsp;<\/strong>Moselhy HF, Reid RG, Yousef S, Boyle SP.<br><strong>Journal:&nbsp;<\/strong>J Lipid Res&nbsp;(2013):&nbsp;852<\/p>\n\n\n\n<p style=\"font-size:14px\">Antioxidant properties of Krebs cycle intermediates against malonate pro-oxidant activity in vitro: a comparative study using the colorimetric method and HPLC analysis to determine malondialdehyde in rat brain homogenates<br><strong>Authors:&nbsp;<\/strong>Puntel RL, Roos DH, Grotto D, Garcia SC, Nogueira CW, Rocha JB.<br><strong>Journal:&nbsp;<\/strong>Life Sci&nbsp;(2007):&nbsp;51<\/p>\n\n\n\n<p style=\"font-size:14px\">Malondialdehyde as biomarker of oxidative damage to lipids caused by smoking<br><strong>Authors:&nbsp;<\/strong>Lykkesfeldt J., undefined<br><strong>Journal:&nbsp;<\/strong>Clin Chim Acta&nbsp;(2007):&nbsp;50<\/p>\n\n\n\n<p style=\"font-size:14px\">Rapid quantification of malondialdehyde in plasma by high performance liquid chromatography-visible detection<br><strong>Authors:&nbsp;<\/strong>Grotto D, Santa Maria LD, Boeira S, Valentini J, Charao MF, Moro AM, Nascimento PC, Pomblum VJ, Garcia SC.<br><strong>Journal:&nbsp;<\/strong>J Pharm Biomed Anal&nbsp;(2007):&nbsp;619<\/p>\n\n\n\n<p style=\"font-size:14px\">Glaucoma and oxidative stress. Determination of malondialdehyde&#8211;a product of lipid peroxidation<br><strong>Authors:&nbsp;<\/strong>Faschinger C, Schmut O, Wachswender C, Mossbock G.<br><strong>Journal:&nbsp;<\/strong>Ophthalmologe&nbsp;(2006):&nbsp;953<\/p>\n\n\n\n<p style=\"font-size:14px\">Short-term oral ingestion of Ginkgo biloba extract (EGb 761) reduces malondialdehyde levels in washed platelets of type 2 diabetic subjects<br><strong>Authors:&nbsp;<\/strong>Kudolo GB, Delaney D, Blodgett J.<br><strong>Journal:&nbsp;<\/strong>Diabetes Res Clin Pract&nbsp;(2005):&nbsp;29<\/p>\n\n\n\n<div style=\"height:63px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-cyan-blue-color\">Application Notes (en Ingles)<\/mark><\/p>\n\n\n\n<p style=\"font-size:14px\"><a href=\"https:\/\/www.aatbio.com\/resources\/application-notes\/a-comparison-of-fluorescent-red-calcium-indicators-for-detecting-intracellular-calcium-mobilization-in-cho-cells\" target=\"_blank\" rel=\"noopener\" title=\"\">A Comparison of Fluorescent Red Calcium Indicators for Detecting Intracellular Calcium Mobilization in CHO Cells<\/a><br><a href=\"https:\/\/www.aatbio.com\/resources\/application-notes\/a-meta-analysis-of-common-calcium-indicators\" rel=\"nofollow\" title=\"\">A Meta-Analysis of Common Calcium Indicators<\/a><br><a href=\"https:\/\/www.aatbio.com\/resources\/application-notes\/a-new-red-fluorescent-robust-screen-quest-rhod-4-ca2-indicator-for-screening-gpcr-ca2-channel-targets\" target=\"_blank\" rel=\"noopener\" title=\"\">A New Red Fluorescent &amp; Robust Screen Quest\u2122 Rhod-4\u2122 Ca2+Indicator for Screening GPCR &amp; Ca2+ Channel Targets<\/a><br><a href=\"https:\/\/www.aatbio.com\/resources\/application-notes\/a-new-robust-no-wash-flipr-calcium-assay-kit-for-screening-gpcr-and-calcium-channel-targets\" target=\"_blank\" rel=\"noopener\" title=\"\">A New Robust No-Wash FLIPR Calcium Assay Kit for Screening GPCR and Calcium Channel Targets<\/a><br><a href=\"https:\/\/www.aatbio.com\/resources\/application-notes\/a-novel-fluorescent-probe-for-imaging-and-detecting-hydroxyl-radical-in-living-cells\" target=\"_blank\" rel=\"noopener\" title=\"\">A Novel Fluorescent Probe for Imaging and Detecting Hydroxyl Radical in Living Cells<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Kit de ensayo de peroxidaci\u00f3n lip\u00eddica (MDA) colorim\u00e9trica intracelular, Cell Meter\u2122. Este kit ofrece el m\u00e9todo m\u00e1s r\u00e1pido y conveniente para medir MDA sin los pasos de calentamiento TBARS.<\/p>\n","protected":false},"featured_media":3080,"template":"","al_product-cat":[34],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/al_product\/3071"}],"collection":[{"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/al_product"}],"about":[{"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/types\/al_product"}],"version-history":[{"count":7,"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/al_product\/3071\/revisions"}],"predecessor-version":[{"id":3750,"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/al_product\/3071\/revisions\/3750"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/media\/3080"}],"wp:attachment":[{"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/media?parent=3071"}],"wp:term":[{"taxonomy":"al_product-cat","embeddable":true,"href":"https:\/\/nuevo22.cidsamexico.com\/index.php\/wp-json\/wp\/v2\/al_product-cat?post=3071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}